Duplo DB-200 User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
15
The fastest speed of settings that AUTO mode can perform is:
TR1 = 2 sec., TR2 = 0.5 sec., TR3 = 1 sec., TR4 = 0.5 sec., TR5 = 0.5 sec.
Note that the book making speed depends on thickness of the book and the loading
technique for the paper and cover.
ERROR DISPLAY:
LED Display Description Cause of Error
ERR = L1 Clamp station is 1. MT1 - fuse blown.
not in the home position. 2. LS1 - sensor is bad.
3. MT1 - motor problem.
ERR = L2 Clamp station is 1. MT1 - fuse blown.
not in the left holding 2. LS2 - sensor bad.
position. 3. MT1 - motor problem.
ERR = L3 Nipping station is unable 1. MT2 - fuse blown.
to reach the lowest 2. LS3 - sensor bad.
position. 3. MT2 - motor problem.
ERR = L4 Nipping station is unable 1. MT2 - fuse blown.
to reach the highest 2. LS4 - sensor bad.
position. 3. MT2 - motor problem.
ERR = T1 After warm up more than 1. Heater fuse blown.
one hour, binder is not 2. Temperature switch bad.
ready to bind. 3. Heater bad.
TEMP ERROR Temperature too low. 1. Heater fuse blown.
2. Temperature switch bad.
3. Heater bad.
HALF00 Skip from Cold to Hot. 1. Stand by sensor bad.
2. Thermostat bad.
Note: Check all electrical connectors of appropriate items when
troubleshooting errors.
Page view 17